Across Industries

Chromatography Solutions Across Multiple Industries

Sykam instruments are at work worldwide — analyzing drinking water, profiling amino acids in clinical samples, testing pharmaceutical purity, monitoring industrial processes, and ensuring food safety.

Laboratory team working with Sykam chromatography systems; analyst reviewing a chromatogram on screen
Scientist preparing samples on a Sykam S 433 Amino Acid Analyzer in a laboratory

Protein & physiology

Amino Acid Analysis

Unlock complete nutritional profiling with Sykam's S 433 Amino Acid AnalyzerS 433 — Automatic amino acid analyser Classical ion-exchange separation with modern HPLC automation, post-column derivatisation, and validated buffer and column packages.—the benchmark for fast, precise quantification across industries. Whether analyzing protein quality in feed, cereals, and fermentation products or assessing physiological samples like plasma and urine, the S 433 offers picomole-level sensitivity and AOAC, European Pharmacopoeia, and VDLUFA-validated performance. Our LCA K06/Na columnsSeparation columns Pre-packed Sykam columns for hydrolysate amino acid profiles—including LCA K06/Na for fast hydrolysate runs under 60 minutes. deliver full hydrolysate analysis in under 60 minutes, while the LCA K07/Li setupPhysiological amino acid columns LCA K07/Li and related chemistries for extended physiological screening—50+ compounds in complex matrices. covers over 50 compounds in complex fluids within 120 minutes. Validated prep methods prevent methionine interference and preserve sample integrity, ensuring regulatory compliance and defensible nutritional data. Trusted by research labs, biotech firms, and feed manufacturers, Sykam's automation, calibration standards, and GLP-compliant reporting deliver unbeatable accuracy and speed.

Environmental compliance

Water & Environmental Analysis

Meet environmental standards with Sykam's S 150 Ion Chromatography SystemS 150 / S 151 — Ion chromatographs Pre-configured IC with conductivity detection, auto-suppression, and column thermostat—anions, cations, and organic acids for water and environmental matrices. for complete water quality assessment. Ideal for municipal, industrial, and research applications, it measures anions, cations, and organic acids on a unified platform. Auto-suppressor technology enhances trace detection of chloride, nitrate, sulfate, bromide, and phosphate; optional preconcentration enables PPB-level sensitivity for ultra-pure water. Intelligent column switching and precise temperature control reduce analysis time while ensuring stable retention and resolution. Backed by global technical support, method development, and troubleshooting expertise, the S 150 provides reliable, defensible water quality data for any matrix—from drinking to wastewater.

Laboratory water analysis station with Sykam ion chromatography equipment for environmental IC methods

Regulated industries

Pharma & Biotech

Accelerate compliance and streamline development with Sykam's modular HPLC solutionsAnalytical HPLC systems Configurable S 600 Series stacks—pumps, autosamplers, ovens, and detectors integrated for pharmaceutical QC and method development. for pharmaceutical QC. From API quantification and impurity profiling to amino acid testing of biologics and radiopharmaceutical purity checks, our systems satisfy global regulatory demands. UV/Vis and PDA detectorsUV/Vis and diode-array detectors Variable-wavelength UV/Vis (S 3245 / S 3250) and PDA (S 3345 / S 3350) covering 190–1,015 nm for spectral identification and purity work. cover 190–1,015 nm for full-spectrum identification, while the S 433 AnalyzerS 433 amino acid analyser Automated ion-exchange amino acid analysis with picomole-level quantification for protein hydrolysates and biologics. quantifies proteins with 10 picomole precision. ChromStar 7 softwareChromStar 7 Instrument control, evaluation, audit trails, electronic signatures, and server options for regulated laboratories—21 CFR Part 11–ready workflows. ensures FDA 21 CFR Part 11 compliance via secure audit trails, electronic signatures, and locked result files. With 30 years of proven partnership, Sykam supports method development through production—delivering modular systems and documentation that speed approvals and ensure data integrity.

Scientist using a Sykam modular HPLC system for pharmaceutical analysis in a laboratory

Nutrition & safety

Food & Beverage

Deliver transparent nutrition labeling with Sykam's chromatography systemsSykam product range Systems, components, columns, and software from a single manufacturer—matched for food and beverage QC workflows. for food and beverage quality control. The S 433 Amino Acid AnalyzerS 433 amino acid analyser Verified protein and amino acid composition for labeling claims, with AOAC-oriented method support on Sykam columns and buffers. verifies protein composition in supplements, plant-based foods, and dairy or meat products, using AOAC-validated protocols for defensible claims. Complementary IC systemsIon chromatography Anion, cation, and organic acid analysis with conductivity detection for minerals, acids, and additives in food matrices. quantify organic acids and minerals while HPLC with RIRI 2000 refractive index High-sensitivity RI detection for sugars and non-UV analytes under isocratic conditions. and ELSDZAM 3000 ELSD Evaporative light scattering for gradients and non-chromophoric compounds in food and natural products. detectors handle sugars and non-UV compounds—offering full nutrient profiling from a single setup. Fast amino acid runs (60–120 minutes) accelerate release decisions, and GLP-compliant data management strengthens supplier verification programs. Sykam helps food brands maintain precision, speed, and competitive quality assurance.

Food and beverage laboratory: scientists with Sykam HPLC and chromatography data for food quality analysis

Operations & scale-up

Industrial Monitoring & Process Control

Optimize performance and prevent costly downtime with Sykam's real-time monitoring solutions. IC systemsIon chromatography Conductivity-based IC for cooling water, boiler feed, and process streams—trace anions and cations before corrosion or scaling. with conductivity detection manage cooling water and boiler feed chemistry, identifying ionic contaminants before corrosion occurs. Modular HPLC setupsModular HPLC Analytical and semi-prep stacks for in-process impurity tracking and product purity verification across production lines. enable impurity tracking and product purity verification across production lines, with gradient switching maximizing capacity. Preparative HPLC systemsPreparative HPLC High-flow preparative pumps, valves, and fraction control for purification at scale—up to 1,000 mL/min class flows depending on configuration. handle flow rates up to 1,000 mL/min, using PEEK columnsPEEK column hardware Metal-free preparative and analytical column bodies—chemical resistance for aggressive solvents and high-pressure operation. rated to 150 bar for safe corrosive solvent use. With 30+ years of expertise, Sykam turns process data into actionable insight—improving safety, yields, and profitability.

Operator using a Sykam industrial chromatography system with live chromatogram display for process monitoring

Healthcare & research

Clinical & Life Sciences

Advance diagnostic discovery with Sykam's amino acid analyzers and separation technologies for clinical and life science labs. The S 433S 433 amino acid analyser Screening and quantification of physiological amino acids and related metabolites from plasma, serum, and urine. screens plasma, urine, and serum for 50+ amino acids and metabolites at 10 picomole sensitivity—identifying markers for metabolic and urea cycle disorders. The S 600 HPLC systemS 600 Series HPLC Pre-configured modular HPLC—combine UV/Vis, PDA, RI, and more for SEC/GPC and analytical characterisation. supports size exclusion and polymer analysis for protein characterization and biotech research. Beyond diagnostics, Sykam enables biodiversity projects like bee2diversitybee2diversity Research collaboration combining chromatography with DNA sequencing and molecular fingerprinting—pollen-based plant biodiversity assessment., using automated pollen analysis to monitor ecological health. With GLP-qualified systems and comprehensive method libraries, Sykam empowers researchers to translate analytical results into clinical and environmental breakthroughs.

Clinical laboratory: scientist with Sykam plasma amino acid profiling system and sample analysis